I

IREN

Operates renewable-powered AI GPU cloud infrastructure

Reliability Engineering Advisor - Electrical & Power

Power Systems EngineeringConfirmed live in the last 24 hours
Full-timeFort Worth, TX, USA

About the Job

Requirements

  • A bachelor's degree in Electrical Engineering or a related discipline is required.
  • At least 10 years of experience in electrical reliability, maintenance engineering, or critical-facilities electrical operations, with demonstrable data center experience across high-, medium-, and low-voltage systems.
  • Deep working knowledge of data center electrical architecture and procedures, including utility intake and substations, medium- and low-voltage switchgear, transformers, generators and paralleling, automatic and static transfer switches, uninterruptible power supply and battery systems, power distribution units, remote power panels and busway, protection, grounding, and electrical power monitoring systems; N+1 and 2N topologies; maintenance bypass; and concurrent maintainability.
  • Experience developing and executing switching orders, methods of procedure, emergency operating procedures, and energized/de-energized work controls; competence in lockout/tagout and electrical safety under NFPA 70E and OSHA 29 CFR 1910 Subpart S.
  • Experience with electrical acceptance and maintenance testing to ANSI/NETA Acceptance Testing Specifications and Maintenance Testing Specifications, including transformer, breaker, relay, cable, and battery testing, thermography, and ultrasonic surveys.
  • Proven root-cause analysis capability using structured methods such as fault tree analysis, event and causal factor charting, Apollo/TapRooT or equivalent, and failure mode and effects analysis/failure mode, effects, and criticality analysis, with the ability to distinguish failure symptom, mode, mechanism, and root cause.
  • Working command of governing standards: NFPA 70 (National Electrical Code), NFPA 70B, NFPA 70E, NFPA 110/111; IEEE 3007.2, IEEE 493, IEEE 1584, IEEE C37 and C57 series, IEEE 450/1188/1106; ANSI/NETA ATS, MTS, and ETT; Uptime Institute Tier and TIA-942 practices; and ISO 55001.
  • Experience building and loading asset maintenance strategies into a computerized maintenance management system; Fiix is preferred, with Maximo and SAP PM also relevant. Experience working with electrical power monitoring systems and power-quality data, and familiarity with reliability analytics including mean time between failures/mean time to repair, Weibull analysis, Pareto analysis, bad-actor analysis, P-F intervals, and condition-based strategy design.
  • Experience writing operating limits and defending maintenance frequencies to original equipment manufacturers and site leads.
  • Experience designing or operating a self-perform maintenance model against an original equipment manufacturer service agreement, including the responsibility matrix, qualification criteria, and warranty-protection conditions.
  • A Professional Engineer license, Certified Maintenance & Reliability Professional certification, Certified Reliability Engineer certification, or NETA/ETT Level III–IV certification is an asset.
  • Regular travel to the Childress campus and other IREN sites is required, with availability to support electrical incidents outside normal hours as needed.
  • Pre-employment screening, including a background check and substance testing, may be required according to company policies.

Responsibilities

  • Own the enterprise high-, medium-, and low-voltage maintenance and testing strategies with a documented technical basis that meets IEEE, NFPA, NETA, and original equipment manufacturer requirements; set the criticality-driven testing regime for campuses; and publish electrical operating limits and guardrails for campuses and the integrated operations centre.
  • Own electrical switching, isolation, and testing standards; develop, review, and approve switching orders, methods of procedure, emergency operating procedures, and energized-work controls; witness high-consequence switching, transfers, load-bank tests, and integrated systems tests; and keep protection settings, coordination and arc-flash studies, and single-line diagrams current and reflected in procedures.
  • Act as the function's authority on electrical codes and standards; review site programs for conformance to NFPA 70B/70E, IEEE, and NETA; support audits and regulator and customer evidence requests; and maintain the electrical testing and inspection records framework.
  • Lead failure analysis for electrical asset failures and serve as the technical member of asset-related incident investigations, contributing asset and maintenance factors to health, safety, and environment-led investigations; define corrective and preventive actions and verify closure; run bad-actor analysis; and determine fleet applicability through technical advisories, fleet inspections, strategy or spares changes, and original equipment manufacturer engagement.
  • Apply reliability-centered maintenance, failure mode and effects analysis/failure mode, effects, and criticality analysis, and reliability analytics to electrical systems; design condition-monitoring programs, including thermography, ultrasonic/partial discharge, dissolved gas analysis, battery monitoring, and power quality, that inform maintenance decisions; evaluate redundancy, single points of failure, and common-mode risk across the topology; review electrical changes through operational management of change; and provide reliability input to specifications, acquisition, commissioning/integrated systems testing and handover, lifecycle, obsolescence, and critical-spares decisions.
  • Define the division between original equipment manufacturer service and IREN's trained staff for each electrical asset class, including uninterruptible power supply and batteries; set the responsibility matrix, qualification criteria, procedure governance, and warranty-protection conditions with Procurement; and build competency that reduces reliance on original equipment manufacturer service while protecting coverage, safety, and cybersecurity.
  • Provide day-to-day technical support and functional direction to Regional Asset Managers, site Planning & Reliability teams, and Operations; review fit-for-purpose deviations; support incident response and recovery; advise on energized-work decisions; conduct electrical readiness reviews at each campus stage; and witness commissioning and acceptance testing.
  • Mentor site reliability engineers, electrical engineers, and technicians, and contribute to competency standards and procedure quality.
  • Maintain electrical reliability key performance indicators and report performance, risk, and required actions to function and site leadership; feed campus results and bad actors back into the enterprise strategy.

About the Company

IREN

Operates renewable-powered AI GPU cloud infrastructure

IREN runs renewable-powered AI cloud and digital infrastructure by operating data centers and GPU clusters. Customers access high-performance NVIDIA GPUs and AI training/inference infrastructure through cloud-based services powered by grid-connected and renewable energy assets. It differentiates itself through full vertical integration of energy assets with compute infrastructure and a focus on North America. The company aims to provide scalable, renewable-powered AI compute for enterprises and developers to support large-scale AI workloads.

Company size
501-1,000
Company stage
IPO
Headquarters
Sydney NSW, Australia
Founded
2018

Recently Posted Jobs

Explore more opportunities at IREN

See more jobs