M

Methodist Health System

Nonprofit, faith-based integrated health system

Nuclear Medicine Tech - Part Time

Diagnostics & Laboratory ProfessionalsConfirmed live in the last 24 hours
Part-timeFremont, NE, USANo salary listed

About the Job

Requirements

  • Must be a graduate of a nuclear medicine program from an accredited college.
  • Must hold certification to practice Nuclear Medicine Technology through the American Registry of Radiologic Technologists or as a Certified Nuclear Medicine Technologist.
  • Must obtain Department of Transportation Hazmat Radioactive Materials certification within 90 days of hire.
  • Must be able to provide transportation to other campus locations within a reasonable timeframe; when on call, the timeframe is within 20 minutes.
  • Must obtain current American Heart Association Basic Life Support certification within three months of hire; it is strongly preferred at the time of hire.
  • Must participate in mandatory in-services and continuing education as required by policies, procedures, external agencies, and the supervisor.
  • Must be able to communicate and interact effectively with patients, family members, hospital personnel, and coworkers.
  • Must be able to organize and perform multiple tasks, solve problems, and prioritize work assignments.
  • Must be able to exert up to 50 pounds of force and perform the listed physical activities, including standing, walking, lifting, pushing, pulling, keyboarding, and seeing.
  • Must comply with applicable radiation-safety regulations and procedures.

Responsibilities

  • Use a scanner to create images of various areas of patients' bodies.
  • Follow manufacturer recommendations for imaging-equipment quality control, identify defects on daily floods before patient use, and maintain complete quality-control records.
  • Evaluate camera detector uniformity against manufacturer specifications, initiate corrective action when necessary, and perform linearity, spatial-resolution, sensitivity, and SPECT quality-control checks, including high-count uniformity flood, center of rotation, energy correction, detector alignment, and visible degradation checks.
  • Perform daily dose-calibrator and survey-meter checks.
  • Provide patient comfort and care before, during, and after procedures, including monitoring intravenous lines, oxygen supplies, and drains.
  • Assess and respond to patient needs before, during, and after procedures, including medication reconciliation when necessary.
  • Communicate appropriately with patients and respect their rights; maintain a safe environment for patients and staff in accordance with standard precautions.
  • Recognize and respond to medical emergencies.
  • Review the appropriateness of study indications and consult authorized personnel to ensure the proper study is ordered.
  • Verify patient identity and relevant information, including name, date of birth, medical record number, last menstrual period, and pregnancy or breastfeeding status.
  • Obtain pertinent medical histories and ensure pre-study preparation is complete before procedures begin.
  • Ensure informed consent is obtained when necessary and provide patient education.
  • Check patient clothing and linens for objects that could cause image artifacts.
  • Maintain adequate medication and pharmaceutical supplies.
  • Schedule patients in a timely manner and determine the best sequence for patients.
  • Maintain Syntrac records of patient doses, quality-control procedures, patient reports, and other required data.
  • Establish or verify venipuncture access using aseptic technique.
  • Wait the appropriate interval after isotope administration before beginning imaging procedures.
  • Acquire images using established protocols and appropriate positioning to demonstrate pathology while accommodating patient limitations.
  • Review images to ensure the correct information is supplied.
  • Prepare patients for electrocardiograms, recognize and respond to electrocardiogram changes, identify parameters requiring termination of cardiac stress studies, and recognize electrocardiogram patterns appropriate for image gating.
  • Collect, process, and analyze data in accordance with established protocols.
  • Perform computer data manipulations required by standard nuclear medicine procedures, such as activity-curve generation, quantitation, and SPECT slice production.
  • Obtain and maintain sufficient isotope in accordance with anticipated need and license possession limits.
  • Store isotopes in accordance with labeled-product safeguards and radiation-safety requirements.
  • Perform and document wipe testing upon receipt of isotopes and record receipt of radioactive materials in Syntrac.
  • Follow Department of Transportation and radiation-safety guidelines when transporting, receiving, and shipping radioactive materials.
  • Prepare unit doses by measuring radioactivity in the dose calibrator, inspecting physical appearance for color and clarity, and comparing dosage with the identification label on the immediate container.
  • Record use and disposition of radioactive materials in Syntrac, label vials and syringes as required by regulation, and dispense only within authorized dose limits.
  • Maintain compliance with local, state, and federal radiation-safety regulations; stay current on regulatory changes and notify authorities of changes to the radiation-safety program.
  • Maintain required radiation-safety records and post appropriate signs; comply with regulations governing receipt, disposal, and use of radioactive materials.
  • Review personnel-monitoring-device exposure levels monthly and notify appropriate authorities of excessive exposure.
  • Use syringe shields and other shielding configurations to reduce radiation exposure to patients, personnel, and the public.
  • Perform and record weekly wipe testing and daily work-environment surveys, take appropriate action if contamination is found, and notify the Radiation Safety Officer when action is required.
  • Retain radioactive material for 10 half-lives before disposal and maintain long- and short-term radioactive-material storage.
  • Use protective devices, shields, monitors, and other equipment consistent with ALARA principles; decontaminate spills and other inappropriate radiation releases.
  • Educate patients and families while using techniques that minimize radiation exposure to patients, the public, and health care personnel.
  • Assist in developing policies and procedures and participate in total quality management and process improvement.
  • Process quality images for accurate and timely radiologist interpretation by correctly labeling images with the date, patient name, radiopharmaceutical, and dosage, and storing them in the Picture Archiving and Communication System with correct patient matching.
  • Float from the primary Fremont cardiac clinic to other greater Omaha locations as needed.
  • Perform other duties as assigned.

Desired Qualifications

  • Experience in a related field is preferred but not mandatory.
  • Current American Heart Association Basic Life Support certification is strongly preferred at the time of hire.

About the Company

Methodist Health System

Nonprofit, faith-based integrated health system

Methodist Health System operates a nonprofit, faith-based network of hospitals and physician clinics across Dallas-Fort Worth, offering primary care, cardiology, orthopedics, women's health, gastroenterology, and emergency care. Its network includes several medical centers and Methodist Medical Group's clinics. What sets Methodist Health System apart is its covenant tie to the North Texas Conference of the United Methodist Church and its sizable charity care commitment. The goal is to improve and save lives through compassionate, quality healthcare.

Company size
Not listed
Company stage
Not listed
Total funding
Not listed
Headquarters
Not listed
Founded
Not listed

Recently Posted Jobs

Explore more opportunities at Methodist Health System

See more jobs