C

Cloudflare

Secures websites and runs apps on its network

Data Center Architect

Building Services EngineeringPosted on Nov 11
Full-timeHybrid

About the Job

Requirements

  • At least 8 years in data center mechanical, electrical, or physical-layer infrastructure, critical-facility cooling, or structured cabling, including architecture or technical design leadership.
  • A bachelor's degree in Electrical or Mechanical Engineering or a related field, or equivalent practical experience.
  • Experience delivering liquid-cooled compute infrastructure from requirements through commissioning or production handover; conventional HVAC experience alone does not qualify.
  • Ability to create and review electrical single-line diagrams and schematics, with hands-on medium-voltage and low-voltage system design including protection, selectivity, and grounding.
  • Strong command of thermodynamics, heat transfer, fluid mechanics, hydraulic calculations, pump and heat-exchanger selection, and cooling performance under variable conditions.
  • Practical experience with cooling distribution units, facility and technology cooling loops, rack distribution, coolant compatibility, leak detection, and the interfaces between liquid-cooled hardware and facility systems.
  • Strong knowledge of copper Ethernet, single-mode and multimode fiber, patching systems, LC and MPO/MTP connectivity, optical loss budgets, polarity, cable management, and applicable test methods.
  • Experience in colocation environments, including cross-connect delivery, diverse physical paths, and the practical constraints of building inside third-party facilities.
  • Ability to write and critically review basis-of-design documents, P&IDs, electrical and mechanical specifications, equipment selections, operating sequences, and test plans.
  • Working knowledge of the National Electrical Code, National Fire Protection Association standards, Underwriters Laboratories standards, mechanical and plumbing codes, TIA and ISO/IEC structured-cabling standards, relevant ASHRAE data center guidance, and manufacturer operating requirements; ability to apply them with qualified local engineering partners.
  • Experience evaluating resilience and maintainability, participating in commissioning, and resolving system-level problems across equipment and organizational boundaries.
  • Experience directing design consultants, contractors, installation partners, or remote hands, with clear ownership of technical decisions and acceptance outcomes.
  • Clear written and verbal communication across disciplines and time zones, and ability to run several projects with limited oversight.
  • Legally authorized to work in the United States on a continuing and permanent basis without company sponsorship.

Responsibilities

  • Build and maintain reference designs, standards, templates, and libraries for power, liquid cooling, and connectivity for AI and high-density compute, covering rack, row, and site interfaces.
  • Translate heat loads, electrical loads, port counts, network topologies, and growth plans into engineering requirements, and establish site and rack qualification criteria.
  • Assess provider power and cooling availability, utility and backup capacity, water supply and return conditions, hydraulic capacity, upstream heat rejection, expansion headroom, maintenance constraints, and contractual boundaries; provide documented go/no-go recommendations and risks.
  • Lead medium-voltage and low-voltage electrical architecture, including single-line diagrams, power distribution, switchgear and UPS topology, busway and PDU design, grounding, and bonding.
  • Design physical AC and DC power infrastructure, including power conversion, backup generation, energy storage, and distribution, with attention to fault levels, selectivity, and maintainability.
  • Validate electrical designs using load-flow, short-circuit, arc-flash, and selectivity studies, checking results against measured performance where possible.
  • Define digital power requirements for monitoring, metering, protection coordination, and control; work with controls and operations teams on alarm thresholds, trend retention, remote monitoring, and BMS/SCADA integration.
  • Incorporate NEC, NFPA, UL, and OCP power and rack specifications into forward-looking electrical designs.
  • Own the liquid-cooling architecture and roadmap; develop repeatable direct-to-chip designs and evaluate liquid-to-liquid, liquid-to-air, rear-door, and other approaches against deployment needs.
  • Design and validate hydraulic systems through flow and pressure-drop calculations, pipe sizing, pump selection, balancing, and control requirements; validate at partial load, during expansion and maintenance, and in failure scenarios.
  • Specify and qualify CDUs, heat exchangers, pumps, manifolds, hoses, quick-disconnects, valves, and instrumentation; coordinate rack access, piping routes, service clearances, and installation sequencing with electrical, cabling, hardware, and structural disciplines.
  • Set manufacturer-aligned coolant-integrity and serviceability requirements for fluid quality, material compatibility, cleanliness, filtration, corrosion control, condensation prevention, and leak detection; ensure safe and maintainable isolation, fluid handling, component replacement, and servicing.
  • Own physical-layer connectivity architecture and reference designs for rack, row, cage, and site connectivity, including copper and fiber distribution, patch-panel placement, cross-connect demarcations, diverse routes, and reserved expansion capacity.
  • Specify fiber and copper media, connectors, trunks, cassettes, and patching for equipment reach and performance; validate optical loss budgets, connector counts, polarity, breakouts, bend radius, and compatibility across hardware generations.
  • Produce buildable pathway layouts, fiber schedules, port-to-port patching plans, cable-length schedules, bills of materials, and installation specifications.
  • Qualify meet-me-room access, provider pathways, cross-connect options, demarcation points, and route diversity; define handoffs with data center providers, carriers, ISPs, and the network strategy team.
  • Coordinate white-space layouts for rack access, airflow, liquid-cooling pipes and manifolds, power segregation, pathway capacity, and expansion; coordinate supports, bonding, grounding, and firestopping with responsible disciplines and providers.
  • Evaluate redundancy, shared failure dependencies, cooling and power interruptions, and thermal ride-through; agree protective responses with hardware and operations teams for pump or CDU failure, facility-cooling loss, leaks, sensor faults, control failures, and power events.
  • Define operational visibility and control requirements for temperatures, pressures, flows, power metering, leak alarms, equipment status, and capacity telemetry.
  • Own basis-of-design documents, single-line diagrams, P&IDs, cabling and equipment schedules, interface requirements, scopes, responsibility matrices, review gates, and acceptance criteria; review partner designs and contractor submittals, resolve RFIs and technical disputes, and drive deviations to documented closure.
  • Guide contractors and remote hands through new deployments, expansions, migrations, and remediation; coordinate installation sequencing, methods of procedure, change controls, and rollback plans with deployment and operations teams to protect running services.
  • Define factory and site acceptance tests across electrical, cooling, and connectivity, including cleanliness and leak-test evidence, flow balancing, loaded performance tests, failure-mode testing, and copper and fiber certification; track deficiencies and verify corrective work before sign-off.
  • Define labeling and connectivity-record standards and ensure as-builts, power and cooling records, patching schedules, cross-connect inventories, and test records reconcile with infrastructure inventory and DCIM.
  • Oversee handover, including deficiency closure, operator training, maintenance procedures, spares, and turnover documentation before production.
  • Support sourcing through RFPs, technical bid evaluation, technical negotiations, supplier qualification, and lifecycle cost analysis; partner with supply chain on prefabricated assemblies, preterminated cabling, rack integration, lead times, and alternatives that reduce field labor without reducing quality.
  • Evaluate phased deployment, consumption, and retrofit options to reduce energy and water use.
  • Investigate incidents and recurring installation defects with network and operations teams, and feed commissioning and operating results back into designs, standards, and quality checks.

Desired Qualifications

  • Professional Engineer, Chartered Engineer, or equivalent registration in electrical or mechanical engineering.
  • BICSI RCDD, DCDC, or a comparable credential.
  • Experience with high-density GPU platforms, OCP rack, power, and cooling interfaces, or qualification across multiple hardware and cooling suppliers.
  • Experience with hydraulic and electrical modeling tools such as AFT Fathom, PIPE-FLO, ETAP, or SKM; thermal or CFD modeling; and validating models against measured performance.
  • Experience with high-density optical distribution, parallel optics, preterminated assemblies, and cabling transitions across successive network generations.
  • Experience with modular or prefabricated power or cooling infrastructure, live-site retrofits, DCIM platforms, automated connectivity or telemetry analysis, or lifecycle energy and water performance.
  • Familiarity with Cloudflare-relevant network environments, including optical transport, ISP interconnection, out-of-band management, and liquid-cooled rack integration.

About the Company

Cloudflare

Secures websites and runs apps on its network

Cloudflare operates a network that protects websites, delivers online content and runs applications closer to their users. Businesses connect websites and internal systems to its services to filter malicious traffic, control access and improve performance, with security and computing running on shared infrastructure. Developers combine application code, object storage and databases with the network used for content delivery and traffic protection. Cloudflare earns revenue from subscriptions and usage charges, with free plans for basic features and negotiated contracts for larger organizations. Cloudflare was founded in 2009 and is headquartered in San Francisco, California.

Company size
1,001-5,000
Company stage
IPO
Headquarters
San Francisco, CA
Founded
2009

Recently Posted Jobs

Explore more opportunities at Cloudflare

See more jobs