M

M.C. Dean

Designs and deploys secure mission-critical infrastructure

Electrical Testing Field Engineer 3

Power Systems EngineeringConfirmed live in the last 24 hours
Full-timeHamlet, NC, USANo salary listed

About the Job

Requirements

  • The position may require ongoing or intermittent use of a company vehicle, and selected candidates must have an acceptable driving record under company policy.
  • Ability to travel domestically and internationally up to 25%–50% of the time.
  • Applicants must have 5 or more years of relevant electrical experience, or an associate’s degree and 4 or more years of relevant electrical experience, or a bachelor’s degree and 3 or more years of relevant electrical experience.
  • Possess valid and active U.S. work authorization.
  • NETA or NICET certification, or equivalent hands-on experience in electrical testing, is preferred.
  • Strong understanding of ANSI, IEEE, NETA, NFPA, NEC, and OSHA electrical safety standards.
  • Ability to interpret electrical schematics, wiring diagrams, and technical manuals.
  • Proficiency in operating and troubleshooting protective relays, circuit breakers, transformers, switchgear, and other electrical equipment.
  • Experience with test equipment such as Doble, Omicron, Megger, Vanguard, and Fluke meters.
  • Understanding of insulation resistance, power factor, contact resistance, and high-potential testing procedures.
  • Knowledge of medium- and high-voltage systems up to 500 kV, including arc flash hazard analysis.
  • Ability to diagnose system failures using troubleshooting and analytical skills.
  • Willingness to travel as needed and work in industrial, data center, and utility environments.
  • Ability to work safely under minimal supervision and follow industry best practices.
  • Ability to lift, carry, and move objects weighing up to 50 pounds regularly, using proper lifting techniques and safety protocols.
  • Ability to relocate a 12-foot stepladder without assistance.
  • Ability to work at heights up to 60 feet and climb and maintain balance on scaffolds, aerial lifts, catwalks, and ladders.
  • Ability to routinely walk, climb, lift, squat, crawl, kneel, push, pull, and reach overhead.
  • Possess good vision, which may be corrected, ability to see in color, and ability to hear and communicate in English.
  • Ability to use a standard ladder without exceeding its weight limit while carrying tools.
  • Ability to recognize when something is wrong or likely to go wrong.
  • Ability to apply general rules to specific problems to produce reasonable answers.
  • Ability to combine information to form general rules or conclusions, including finding relationships among seemingly unrelated events.
  • Ability to see details at close range, within a few feet.
  • Ability to listen to and understand information and ideas presented through spoken words and sentences.

Responsibilities

  • Install, program, and maintain protective relaying and metering systems used in transmission and distribution operations.
  • Perform electrical tests and repairs to maintain and evaluate in-service relays, prevent and remedy abnormal behavior or failure of transmission and distribution equipment, analyze test results, and interpret electrical diagrams to locate defective equipment.
  • Use hand tools, power tools, meters, and other test equipment in energized electrical rooms, vaults, and substations to install, maintain, repair, and program protective relays and associated wiring and equipment.
  • Apply, read, understand, review, and correct schematic and wiring-diagram blueprints and substation drawings and inspections.
  • Program and operate test equipment and follow safe work practices outlined in the company safety handbook.
  • Commission new relay and metering installations.
  • Coordinate testing, troubleshooting, and repairs of relaying and other equipment with other department personnel.
  • Perform maintenance and testing on relays and associated equipment, including standby generators and display meters.
  • Troubleshoot, repair, and replace components involved in questionable operations and failures.
  • Participate in emergency callouts.
  • Perform other duties, tasks, and special projects as assigned.
  • Perform acceptance and maintenance testing of electrical power systems to ensure compliance with NETA standards.
  • Conduct protective relay testing, calibration, and programming for various manufacturers.
  • Perform circuit breaker and switchgear testing, including timing tests and primary and secondary injection testing.
  • Troubleshoot electrical faults and perform root cause analysis for system failures.
  • Conduct transformer testing, including turns ratio, insulation resistance, and power factor testing.
  • Ensure adherence to electrical safety protocols, including lockout/tagout procedures and personal protective equipment compliance.
  • Maintain detailed test reports and documentation for compliance and client review.
  • Collaborate with engineers, project managers, and clients to support efficient system commissioning and startup.
  • Provide mentorship and technical guidance to junior technicians as needed.

Desired Qualifications

  • Completion of an original equipment manufacturer (OEM)-certified field service training program.

About the Company

M.C. Dean

Designs and deploys secure mission-critical infrastructure

M.C. Dean designs, builds, operates, and maintains integrated cyber-physical systems for mission-critical facilities, secure environments, and large enterprises. Its work spans electrical power, security, telecommunications, life safety, automation and controls, audio-visual, and IT systems, all coordinated through management platforms that support long-term operation and sustainability. The company works end-to-end: it engineers solutions, installs them, and then runs and maintains them to ensure continuous, secure, and resilient performance. What sets it apart is its ability to provide comprehensive, turnkey technology and infrastructure services for critical environments—combining physical systems with digital management to create secure, automated facilities. The goal is to deliver automated, secure, and resilient power and technology systems and the platforms needed to manage them over the long term.

Company size
1,001-5,000
Company stage
Not listed
Total funding
Not listed
Headquarters
Tysons, VA
Founded
1949

Recently Posted Jobs

Explore more opportunities at M.C. Dean

See more jobs