M

M.C. Dean

Designs and deploys secure mission-critical infrastructure

Electrical Test Technician 3

Power Systems EngineeringConfirmed live in the last 24 hours
Full-timeWashington, DC, USA$42 - $51 /hr

About the Job

Requirements

  • Applicants must have at least 7 years of relevant electrical experience and a High School Diploma or GED.
  • Applicants must possess valid, active U.S. work authorization.
  • Applicants must have a strong understanding of ANSI, IEEE, NETA, NFPA, NEC, and OSHA electrical safety standards.
  • Applicants must be able to interpret electrical schematics, wiring diagrams, and technical manuals.
  • Applicants must be able to operate and troubleshoot protective relays, circuit breakers, transformers, switchgear, and other electrical equipment.
  • Applicants must have experience with test equipment such as Doble, Omicron, Megger, Vanguard, and Fluke meters.
  • Applicants must understand insulation resistance, power factor, contact resistance, and high-potential testing procedures.
  • Applicants must know medium- and high-voltage systems up to 500 kV, including arc-flash hazard analysis.
  • Applicants must be able to troubleshoot and diagnose system failures.
  • Applicants must be willing to travel as needed and work in industrial, data center, and utility environments.
  • Applicants must be able to work safely under minimal supervision and follow industry best practices.
  • Applicants must be able to lift, carry, and move objects weighing up to 50 pounds regularly and follow proper lifting techniques and safety protocols.
  • Applicants must be able to relocate a 12-foot stepladder without assistance.
  • Applicants must be able to work at heights up to 60 feet and climb and maintain balance on scaffolds, aerial lifts, catwalks, and ladders.
  • Applicants must routinely walk, climb, lift, squat, crawl, kneel, push, pull, and reach overhead.
  • Applicants must have good vision, including color vision, and the ability to hear and communicate in English.
  • Applicants must be able to use a standard ladder without exceeding its weight limit while carrying tools.
  • Applicants must be able to recognize when something is wrong or likely to go wrong.
  • Applicants must be able to apply general rules to specific problems and produce sensible answers.
  • Applicants must be able to combine information to form general rules or conclusions, including identifying relationships among seemingly unrelated events.
  • Applicants must be able to see details at close range, within a few feet.
  • Applicants must be able to listen to and understand information and ideas presented through spoken words and sentences.

Responsibilities

  • Develop the Electrical Testing Program for the duty site and serve as the subject matter expert for the division’s operations and maintenance program.
  • Manage or train operations staff to operate, monitor, control, and update system control applications; maximize system efficiency and revise operating controls to accommodate facility changes or correct problems and inefficiencies.
  • Assist in developing processes, methods, standard operating procedures, and training programs for operators monitoring and controlling complex mechanical, electrical, life-safety, and building-control systems.
  • Assist in implementing processes and procedures using the computerized maintenance management system to schedule, dispatch, track, and report mechanical, electrical, and plumbing field emergency repairs, adjustments, preventive maintenance, and warranty activities.
  • Manage integration, reliability, and functionality of building control systems, including SCADA, Delta Controls, and life-safety systems.
  • Coordinate with the Program Manager while on duty to optimize monitoring-system performance and meet government energy goals.
  • Provide oversight, troubleshoot, and address operational problems.
  • Assume supervisory responsibility during electrical testing activities.
  • Assist the mechanical, electrical, and plumbing Operations Manager in developing electrical work and project schedules.
  • Assist in developing and implementing operations risk management safety procedures and safety meetings; generate safety reports and maintain related records.
  • Troubleshoot SCADA, building management systems, relay testing, and SKM power systems; conduct short-circuit and arc-flash studies.
  • Perform acceptance and maintenance testing of electrical power systems to ensure compliance with NETA standards.
  • Conduct protective relay testing, calibration, and programming for various manufacturers.
  • Perform circuit-breaker and switchgear testing, including timing and primary and secondary injection testing.
  • Troubleshoot electrical faults and perform root-cause analysis for system failures.
  • Conduct transformer testing, including turns-ratio, insulation-resistance, and power-factor testing.
  • Ensure adherence to electrical safety protocols, including lockout/tagout procedures and personal protective equipment compliance.
  • Maintain detailed test reports and documentation for compliance and client review.
  • Collaborate with engineers, project managers, and clients to support efficient system commissioning and startup.
  • Provide mentorship and technical guidance to junior technicians as needed.

Desired Qualifications

  • NETA or NICET certification, or equivalent hands-on experience in electrical testing.
  • Original equipment manufacturer-certified field-service training program.

About the Company

M.C. Dean

Designs and deploys secure mission-critical infrastructure

M.C. Dean designs, builds, operates, and maintains integrated cyber-physical systems for mission-critical facilities, secure environments, and large enterprises. Its work spans electrical power, security, telecommunications, life safety, automation and controls, audio-visual, and IT systems, all coordinated through management platforms that support long-term operation and sustainability. The company works end-to-end: it engineers solutions, installs them, and then runs and maintains them to ensure continuous, secure, and resilient performance. What sets it apart is its ability to provide comprehensive, turnkey technology and infrastructure services for critical environments—combining physical systems with digital management to create secure, automated facilities. The goal is to deliver automated, secure, and resilient power and technology systems and the platforms needed to manage them over the long term.

Company size
1,001-5,000
Company stage
Not listed
Total funding
Not listed
Headquarters
Tysons, VA
Founded
1949

Recently Posted Jobs

Explore more opportunities at M.C. Dean

See more jobs